Showing posts with label Economizer. Show all posts
Showing posts with label Economizer. Show all posts

Super Heater Tube

A superheater is a device used to convert saturated steam or wet steam into dry steam used for power generation or processes. There are three types of superheaters namely: radiant, convection, and separately fired. A superheater can vary in size from a few tens of feet to several hundred feet (a few metres or some hundred metres).
A radiant superheater is placed directly in the combustion chamber.

A convection superheater is located in the path of the hot gases.

A separately fired superheater, as its name implies, is totally separated from the boiler.

A superheater is a device in a steam engine, when considering locomotives, that heats the steam generated by the boiler again, increasing its thermal energy and decreasing the likelihood that it will condense inside the engine.[1][2] Superheaters increase the efficiency of the steam engine, and were widely adopted. Steam which has been superheated is logically known as superheated steam; non-superheated steam is called saturated steam or wet steam. Superheaters were applied to steam locomotives in quantity from the early 20th century, to most steam vehicles, and to stationary steam engines. This equipment is still an integral part of power generating stations throughout the world.


Locomotive use
In steam locomotive use, by far the most common form of superheater is the fire-tube type. This takes the saturated steam supplied in the dry pipe into a superheater header mounted against the tube sheet in the smokebox. The steam is then passed through a number of superheater elements—long pipes which are placed inside special, widened fire tubes, called flues. Hot combustion gases from the locomotive's fire pass through these flues just like they do the firetubes, and as well as heating the water they also heat the steam inside the superheater elements they flow over. The superheater element doubles back on itself so that the heated steam can return; most do this twice at the fire end and once at the smokebox end, so that the steam travels a distance of four times the header's length while being heated. The superheated steam, at the end of its journey through the elements, passes into a separate compartment of the superheater header and then to the cylinders as normal.

Damper and snifting valve
The steam passing through the superheater elements cools their metal and prevents them from melting, but when the throttle closes this cooling effect is absent, and thus a damper closes in the smokebox to cut off the flow through the flues and prevent them being damaged. Some locomotives (particularly on the London and North Eastern Railway) were fitted with snifting valves which admitted air to the superheater when the locomotive was coasting (drifting). This kept the superheater elements cool and the cylinders warm. The snifting valve can be seen behind the chimney on many LNER locomotives.

Front-end throttle
A superheater increases the distance between the throttle and the cylinders in the steam circuit and thus reduces the immediacy of throttle action. To counteract this, some later steam locomotives were fitted with a front-end throttle—placed in the smokebox after the superheater. Such locomotives can sometimes be identified by an external throttle rod that stretches the whole length of the boiler, with a crank on the outside of the smokebox. This arrangement also allows superheated steam to be used for auxiliary appliances, such as the dynamo and air pumps. Another benefit of the front end throttle is that superheated steam is immediately available. With the dome throttle it took quite some time before the super heater actually provided benefits in efficiency. One can think of it in this way: if one opens saturated steam from the boiler to the superheater it goes straight through the superheater units and to the cylinders which doesn't leave much time for the steam to be superheated. With the front-end throttle, steam is in the superheater units while the engine is sitting at the station and that steam is being superheated. Then when the throttle is opened, superheated steam goes to the cylinders immediately.

Advantages and disadvantages
The main advantages of using a superheater are reduced fuel and water consumption but there is a price to pay in increased maintenance costs. In most cases the benefits outweighed the costs and superheaters were widely used. An exception was shunting locomotives (switchers). British shunting locomotives were rarely fitted with superheaters. In locomotives used for mineral traffic the advantages seem to have been marginal. For example, the North Eastern Railway fitted superheaters to some of its NER Class P mineral locomotives but later began to remove them.

Without careful maintenance superheaters are prone to a particular type of hazardous failure in the tube bursting at the U-shaped turns in the superheater tube. This is difficult to both manufacture, and test when installed, and a rupture will cause the superheated high-pressure steam to escape immediately into the large flues, then back to the fire and into the cab, to the extreme danger of the locomotive crew.

Economizer

An economiser is a device fitted to a boiler which saves energy by using the exhaust gases from the boiler to pre-heat the cold water used the fill it (the feed water).

Flue gases from large boilers are typically 250 - 350°C. Stack Economizers recover some of this heat for pre-heating water. The water is most often used for boiler make-up water or some other need that coincides with boiler operation. Stack Economizers should be considered as an efficiency measure when large amounts of make-up water are used (ie: not all condensate is returned to the boiler or large amounts of live steam are used in the process so there is no condensate to return.)

It consists of an array of vertical cast iron tubes connected to a tank of water above and below, between which the boiler's exhaust gases are passed. This is the reverse arrangement to that of fire tubes in a boiler itself; there the hot gases pass through tubes immersed in water, whereas in an economiser the water passes through tubes surrounded by hot gases. For good efficiencies, the tubes must be free of deposits of soot.

They are often referred to as feedwater heaters and heat the condensate from turbines before it is pumped to the boilers.

The savings potential is based on the existing stack temperature, the volume of make-up water needed, and the hours of operation. Economizers are available in a wide range of sizes, from small coil-like units to very large waste heat recovery boilers.
Stack Economizers should be considered as an efficiency measure when large amounts of make-up water are used (ie: not all condensate is returned to the boiler or large amounts of live steam is used in the process so there is no condensate to return) or there is a simultaneous need for large volumes of hot water.

What is a Boiler Economizer?

A boiler economizer is a heat exchanger device that captures the "lost or waste heat" from the boiler's hot stack gas. The economizer typically transfers this waste heat to the boiler's feed-water or return water circuit, but it can also be used to heat domestic water or other process fluids. Capturing this normally lost heat reduces the overall fuel requirements for the boiler. Less fuel equates to money saved as well as fewer emissions - since the boiler now operates at a higher efficiency. This is possible because the boiler feed-water or return water is pre-heated by the economizer therefore the boilers main heating circuit does not need to provide as much heat to produce a given output quantity of steam or hot water. Again fuel savings are the result. Boiler economizers improve a boiler's efficiency by extracting heat from the flue gases discharged.

Systems Equipment Corporation Boiler Economizers are fabricated from uniquely formed tubular elements, similar to a tear drop or diamond shape. Each economizer is specifically designed to match our clients boiler characteristics in order to maximize efficiency and the use of boiler room space. Because Systems Equipment Corporation Boiler Economizers are manufactured from stainless steel the usual corrosion problems encountered by our competitions designs are eliminated.